Drop Out Fuse
33 kV Product Category
Outdoor drop-out fuse page prepared for the 33 kV product category. The supplied Eaton / Cooper Type L catalogue provides reference configurations; the offered Baocheng model and its applicable ratings remain to be verified.
DRAFT · 33 kV Product Verification Required
Reference Catalogue · Separate 38 / 40.5 kV Configurations
Outdoor Distribution · Model-Specific Selection

Electrical Characteristics
Nominal system voltage
33 kV
Requested voltage category
33 kV
Offered equipment rating
To be confirmed
Current / breaking duty
To be confirmed
What Is the Drop Out Fuse?
Expulsion fuse cutouts are used for overcurrent protection of suitable overhead distribution circuits. Selection requires the system voltage, earthing arrangement, insulation level, continuous current, available fault current and a coordinated fuse link.
Draft — product mapping pending. The supplied document is an Eaton / Cooper Type L catalogue. Its higher-voltage table lists a 40.5 kV polymeric configuration and a 38 kV porcelain configuration. Neither is automatically a verified rating of the requested Baocheng 33 kV product.
The two catalogue configurations have different breaking currents, insulation levels, creepage distances and altitude limits. They remain separate reference tables below. The 12 kV figures, certifications, interchangeability and load-switching claims elsewhere in the catalogue are not transferred to this product.
Technical Specifications & Selection Data
Table 1 — S9FAP1A — Eaton / Cooper Reference Only
| No. | Parameter | Unit | Value |
|---|---|---|---|
| 01 | Insulation / catalogue model | — | Silicone rubber / S9FAP1A |
| 02 | Rated voltage | kV | 40.5 |
| 03 | Rated current | A | 100 |
| 04 | Rated frequency | Hz | 50 |
| 05 | Rated short-circuit breaking current | kA | 6 |
| 06 | Power-frequency withstand, dry / wet | kV | 108 / 91 |
| 07 | Power-frequency withstand across isolating distance, dry / wet | kV | 134 / 109 |
| 08 | Lightning impulse withstand, to earth / across isolating distance | kV | 210 / 243 |
| 09 | Mechanical endurance | operations | 1000 |
| 10 | Altitude limit | m | 2000 |
| 11 | TRV class | — | B |
| 12 | Creepage distance | mm | 1256 |
Table 2 — L9EAP1A — Eaton / Cooper Reference Only
| No. | Parameter | Unit | Value |
|---|---|---|---|
| 01 | Insulation / catalogue model | — | Porcelain / L9EAP1A |
| 02 | Rated voltage | kV | 38 |
| 03 | Rated current | A | 100 |
| 04 | Rated frequency | Hz | 50 |
| 05 | Rated short-circuit breaking current | kA | 8 |
| 06 | Power-frequency withstand, dry / wet | kV | 70 / 60 |
| 07 | Power-frequency withstand across isolating distance, dry / wet | kV | 80 / 60 |
| 08 | Lightning impulse withstand, to earth / across isolating distance | kV | 170 / 200 |
| 09 | Mechanical endurance | operations | 200 |
| 10 | Altitude limit | m | 1000 |
| 11 | TRV class | — | B |
| 12 | Creepage distance | mm | 720 |
Source: supplied Eaton / Cooper Type L catalogue, PDF page 9 (printed page 6). These are third-party reference ratings, not Baocheng product specifications. The catalogue installation drawings on PDF pages 10–11 are expressly for 12 kV and are not used as 33 kV mounting drawings.
Table 3 — 33 kV Product — Outstanding Verification
| No. | Parameter | Unit | Value |
|---|---|---|---|
| 01 | Offered Baocheng model | — | To be confirmed |
| 02 | Equipment rated voltage | kV | To be confirmed against the network maximum voltage |
| 03 | Rated current and breaking duty | — | To be confirmed for the offered model |
| 04 | Mounting dimensions | — | No verified high-voltage installation drawing supplied |
| 05 | Service conditions and test evidence | — | To be confirmed; reference catalogue limits are model-specific |
Drop-Out Fuse: General Arrangement & Operation
Type L Reference Assembly
Illustrative example / 示例图 — Eaton / Cooper catalogue, PDF page 6, Figure 3. This is not a verified 33 kV product structure.
The reference labels the upper terminal, protective hood, contacts, operating ring, fuseholder, hinge, lower terminal and mounting bracket. Insulator form and dimensions depend on the selected model.
01 Coordinated Fuse Link
The fuse link carries normal load current. Its time-current characteristic must coordinate with transformer inrush, feeder loading and adjacent protective devices.
02 Expulsion Interruption
An arc-extinguishing lining generates gas during fuse operation to assist interruption. The cutout, fuseholder and fuse link must form the tested combination for the required fault duty.
03 Visible Open Position
The hinged fuseholder drops after operation. Load-current switching, tool compatibility and restoration procedures require confirmation for the actual offered equipment.
Model-Specific Load-Switching Duty
The catalogue contains both standard and load-break designs. The high-voltage reference table is labelled standard type; the 12 kV load-switching endurance figures must not be applied to these higher-voltage configurations.
Reference Assembly & Fuse-Link Construction
The figures below explain the reference construction only. A confirmed outline and installation drawing for the offered 33 kV-category product is still required.
Type L Assembly — Reference Example
| Illustrative example / 示例图 |
| Eaton / Cooper Figure 3, PDF page 6 |
| Main terminal, insulator and fuseholder labels |
| Not a verified 33 kV mounting drawing |
The original Chinese labels are preserved. This reference explains component relationships only; it does not establish the construction or dimensional interfaces of the offered Baocheng model.
Fuse Link — Reference Construction
| Illustrative example / 示例图 |
| Eaton / Cooper Figure 4, PDF page 6 |
| Fuse element, auxiliary tube and flexible lead |
| No dimensions or compatibility rating inferred |
The reference shows a fuse element, tension member, connection terminal, auxiliary arc-extinguishing tube and lead. Select the actual fuse link using the approved compatibility and time-current data.
Applications, Features & Selection Considerations
Prepare the following information for a 33 kV-category equipment selection. Confirm each item against the final offered model rather than choosing a rating from the category title alone.
Voltage & Earthing
Check maximum voltage across the fuse and system earthing.
Insulation Coordination
Compare impulse levels and creepage with the installation.
Fault Duty
Keep each model’s rated breaking current distinct.
Fuse-Link Selection
Coordinate load, inrush and protection characteristics.
Site & Mounting
Confirm altitude, environment, bracket and terminals.
Technical Documents & Supply Scope
Drop Out Fuse Technical Documents
Request the technical package for the selected configuration:
- Confirmed Baocheng model and approved electrical data sheet.
- Applicable type-test evidence for that exact configuration.
- High-voltage outline, mounting and terminal drawings.
- Fuse-link curves, compatibility and operating instructions.
Inspection & Test Documentation
Request the approved data sheet, insulation and breaking-duty test evidence, and inspection records for the exact cutout and fuse-link combination. Check the tested model, configuration and report scope.
The catalogue contains Eaton / Cooper certification and interchangeability statements, including 12 kV test references. They are not evidence for the offered Baocheng product and are not claimed as its approvals.
Supply Scope to Confirm
- Exact offered model and equipment rated voltage.
- Insulator material, rated current and breaking duty.
- Compatible fuse links and required spare quantity.
- Terminals, brackets and operating-tool requirements.
- Approved inspection documents, quantity and delivery scope.
Reference catalogue accessories and brands are not treated as the agreed Baocheng supply scope. Confirm every included item in the technical quotation.
Installation & Maintenance Review
The supplied dimensional tables cover 12 kV equipment. A matching high-voltage installation drawing is needed before deciding mounting holes, phase clearances or operating space for the requested 33 kV-category unit.
Send the network voltage and earthing arrangement, required cutout rating, load and fault current, fuse-link requirements, site conditions, mounting details and quantity with your inquiry.
Drop Out Fuse FAQ
Does 33 kV identify the equipment rated voltage?
Not by itself. It is the requested product-category title. The supplied third-party reference lists 38 kV and 40.5 kV high-voltage configurations; the offered model and equipment rating still require confirmation.
Can the 38 kV and 40.5 kV reference ratings be combined?
No. S9FAP1A is listed at 40.5 kV, 100 A and 6 kA; L9EAP1A is listed at 38 kV, 100 A and 8 kA. Their insulation, creepage, endurance and altitude limits also differ.
Are these Baocheng-certified product ratings?
No. The tables are explicitly identified as Eaton / Cooper catalogue references. The source does not establish certification or rating equivalence for a Baocheng product.
Are 33 kV installation dimensions available?
The supplied installation drawings on PDF pages 10–11 are marked 12 kV. They have not been reused as 33 kV drawings. Obtain the approved drawing for the offered unit.
Can this product switch load current?
The precise configuration and operating method must be confirmed. Load-switching figures for the catalogue’s 12 kV load-break versions are not ratings for the high-voltage standard-type models.
What is needed to finalise the selection?
Provide the offered model, system maximum voltage and earthing, load and fault duty, insulation requirements, fuse-link characteristic, site conditions, mounting details and quantity.
Related Products
Explore related drop out fuses and fuse cutouts for overhead distribution and transformer protection applications.