6 kV Medium-Voltage Soft Starter
RVS Series

Solid-state starting for medium-voltage motors. The RVS family combines controlled starting, motor supervision and vacuum bypass operation in separate or integrated cabinet configurations.

6 kV motor application · RVS series
SCR control · vacuum bypass
Separate or integrated configuration

RVS series cabinet photographs from the supplied Raynen catalogue, cover. They are source reference images; exact supplied appearance is to be confirmed.

Electrical Characteristics

Nominal system voltage

6 kV

Selected motor voltage

6 kV

Supply frequency

50 / 60 Hz

Control supply

220 V AC ±15%

What Is The RVS Series?

The supplied file is an RVS medium-voltage solid-state motor soft-starter catalogue, version V2025.01. It describes 6 kV and 10 kV configurations, including standard separate units and integrated cabinet arrangements.

This page addresses a 6 kV motor application. Thyristor control adjusts motor voltage during starting; after acceleration, the vacuum bypass contactor connects the motor to the line supply. Selection depends on the motor, driven load and permissible starting duty.

Typical catalogue applications include pumps, fans, compressors, crushers, mixers and conveyors. The product controls starting and stopping; it is not presented as a variable-frequency speed-control drive.

Technical Specification Tables

Table 1 — Electrical & starting data

ParameterCatalogue value
Selected system voltage6 kV; catalogue family covers 6–10 kV AC
Supply frequency50 / 60 Hz, ±2 Hz
Control supply220 V AC ±15%
Starting current setting range1.5–5.0 × Ie
Starting frequency1–6 starts per hour
Starting modesCurrent limit, voltage ramp, current ramp and combined / kick-start modes
Fault memory1,000 records

Sources: PDF page 4 (printed 03–04) and page 7 (printed 09–10). Ie denotes rated current. Settings and duty require motor thermal and acceleration checks; values are not guaranteed performance for every load.

Table 2 — Protection & interfaces

ParameterCatalogue description
Motor protectionOvercurrent, overload, undervoltage, phase loss and other configured functions
Overload classes listed10A / 10 / 20 / 30
Start timeout setting10–120 s
CommunicationsRS-485 / Modbus RTU — confirm configuration
Control methodsLocal, remote dry contacts, PLC or communication
Bypass deviceVacuum contactor

The source describes both standard and optional features. Confirm the selected controls, monitoring and protection scope in the quotation.

Table 3 — Service conditions

ParameterCatalogue value
Ambient temperature−20 to +50 °C
Relative humidity5–95%, non-condensing
AltitudeBelow 1,500 m; derating above this level
Motor types describedThree-phase squirrel-cage induction or synchronous motors

Motor suitability, excitation arrangements where relevant, starting duty and altitude derating require application review.

RVS Series: Design & Operating Principle

Functional Overview

Illustrative example / 示例图 — functional explanation only; no engineering dimensions.

This diagram supports the operating description. It is not an approved primary schematic or switching procedure.

01 · Starting command

The controller applies the configured current-limit or ramp strategy after the required readiness checks.

02 · Thyristor control

Series SCR assemblies regulate the starting voltage. The source describes fibre-optic triggering and isolation between the control and high-voltage sections.

03 · Bypass & supervision

Following starting, the three-phase vacuum bypass contactor closes. Motor protection and operating supervision continue in the configured system.

General Arrangement & Installation Interfaces

Separate Starter Scheme

Original primary circuit from PDF page 6, printed page 07.
ItemDetails
ConfigurationSeparate soft-starter cabinet
Incoming protectionRequires a coordinated feeder cabinet

The source describes this version as requiring a feeder cabinet. Confirm the line-side switching and protection in the complete 6 kV system design.

Integrated Starter Scheme

Original primary circuit from PDF page 6, printed page 08.
ItemDetails
ConfigurationIntegrated line-side VCB and bypass
Source drawing voltage label10 kV example

Illustrative example / 示例图: the original integrated diagram is labelled 10 kV. It explains the catalogue architecture only; it is not an approved 6 kV project circuit. Its voltage label has not been altered.

Applications, Features & Procurement Considerations

Starting flexibility

The catalogue lists current-limit, voltage-ramp and current-ramp strategies, with combined and kick-start functions for suitable applications.

Vacuum bypass

A vacuum bypass contactor carries the running motor circuit after the starting sequence is completed.

Monitoring & communication

HMI supervision, fault history and local / remote control functions can be specified, with RS-485 communication configuration to be confirmed.

Separate or integrated

Separate units require coordinated feeder protection; integrated units include line-side vacuum switching as described in the selected configuration.

Technical Documents & Supply Scope

RVS Series Technical Documents

Original supplied product document, with ratings, configuration information and available drawings. The original source language and annotations are retained.

Inspection & Test Documentation

The supplied Raynen catalogue lists standards for semiconductor equipment, metal-enclosed equipment, enclosure protection and EMC. These references do not establish certification for the proposed supplied package.

Supply Scope To Confirm

Motor nameplate voltage and current; motor power; load torque and inertia; required acceleration time; permissible starting current; starts per hour; separate / integrated enclosure; upstream fault duty; bypass and protection; cable entry; controls and communications.

Maintenance Planning

Agree inspection of the SCR assemblies, cooling, fibre-optic links, contactors, protection and interlocks. Supplier documentation must cover the specific motor and starting duty.

6 kV Medium-Voltage Soft Starter FAQ

No. The supplied document describes a medium-voltage solid-state motor soft starter. Its primary purpose is controlled motor starting and stopping.

It is described as a soft starter with bypass operation after starting, not as a variable-frequency drive for continuous speed control.

The separate design needs a coordinated feeder cabinet. The integrated design combines line-side vacuum switching, soft-start control and bypass functions.

No. Select by motor rated current, load, starting time, duty cycle, ambient temperature and altitude. The catalogue selection tables contain inconsistent entries that need supplier confirmation.

The original integrated example in the supplied catalogue is labelled 10 kV. It is clearly marked as illustrative here and must be replaced by the approved 6 kV project schematic for engineering use.