Medium Voltage Equipment / 6 kV Medium-Voltage Soft Starter
Baocheng Electrical
6 kV Medium-Voltage Soft Starter
RVS Series
Solid-state starting for medium-voltage motors. The RVS family combines controlled starting, motor supervision and vacuum bypass operation in separate or integrated cabinet configurations.
6 kV motor application · RVS series
SCR control · vacuum bypass
Separate or integrated configuration
What Is The RVS Series?
The supplied file is an RVS medium-voltage solid-state motor soft-starter catalogue, version V2025.01. It describes 6 kV and 10 kV configurations, including standard separate units and integrated cabinet arrangements.
This page addresses a 6 kV motor application. Thyristor control adjusts motor voltage during starting; after acceleration, the vacuum bypass contactor connects the motor to the line supply. Selection depends on the motor, driven load and permissible starting duty.
Typical catalogue applications include pumps, fans, compressors, crushers, mixers and conveyors. The product controls starting and stopping; it is not presented as a variable-frequency speed-control drive.
Technical Specification Tables
Table 1 — Electrical & starting data
| Parameter | Catalogue value |
|---|---|
| Selected system voltage | 6 kV; catalogue family covers 6–10 kV AC |
| Supply frequency | 50 / 60 Hz, ±2 Hz |
| Control supply | 220 V AC ±15% |
| Starting current setting range | 1.5–5.0 × Ie |
| Starting frequency | 1–6 starts per hour |
| Starting modes | Current limit, voltage ramp, current ramp and combined / kick-start modes |
| Fault memory | 1,000 records |
Sources: PDF page 4 (printed 03–04) and page 7 (printed 09–10). Ie denotes rated current. Settings and duty require motor thermal and acceleration checks; values are not guaranteed performance for every load.
Table 2 — Protection & interfaces
| Parameter | Catalogue description |
|---|---|
| Motor protection | Overcurrent, overload, undervoltage, phase loss and other configured functions |
| Overload classes listed | 10A / 10 / 20 / 30 |
| Start timeout setting | 10–120 s |
| Communications | RS-485 / Modbus RTU — confirm configuration |
| Control methods | Local, remote dry contacts, PLC or communication |
| Bypass device | Vacuum contactor |
The source describes both standard and optional features. Confirm the selected controls, monitoring and protection scope in the quotation.
Table 3 — Service conditions
| Parameter | Catalogue value |
|---|---|
| Ambient temperature | −20 to +50 °C |
| Relative humidity | 5–95%, non-condensing |
| Altitude | Below 1,500 m; derating above this level |
| Motor types described | Three-phase squirrel-cage induction or synchronous motors |
Motor suitability, excitation arrangements where relevant, starting duty and altitude derating require application review.
RVS Series: Design & Operating Principle
Functional Overview
This diagram supports the operating description. It is not an approved primary schematic or switching procedure.
01 · Starting command
The controller applies the configured current-limit or ramp strategy after the required readiness checks.
02 · Thyristor control
Series SCR assemblies regulate the starting voltage. The source describes fibre-optic triggering and isolation between the control and high-voltage sections.
03 · Bypass & supervision
Following starting, the three-phase vacuum bypass contactor closes. Motor protection and operating supervision continue in the configured system.
General Arrangement & Installation Interfaces
Separate Starter Scheme
| Item | Details |
|---|---|
| Configuration | Separate soft-starter cabinet |
| Incoming protection | Requires a coordinated feeder cabinet |
The source describes this version as requiring a feeder cabinet. Confirm the line-side switching and protection in the complete 6 kV system design.
Integrated Starter Scheme
| Item | Details |
|---|---|
| Configuration | Integrated line-side VCB and bypass |
| Source drawing voltage label | 10 kV example |
Illustrative example / 示例图: the original integrated diagram is labelled 10 kV. It explains the catalogue architecture only; it is not an approved 6 kV project circuit. Its voltage label has not been altered.
Applications, Features & Procurement Considerations
Starting flexibility
The catalogue lists current-limit, voltage-ramp and current-ramp strategies, with combined and kick-start functions for suitable applications.
Vacuum bypass
A vacuum bypass contactor carries the running motor circuit after the starting sequence is completed.
Monitoring & communication
HMI supervision, fault history and local / remote control functions can be specified, with RS-485 communication configuration to be confirmed.
Separate or integrated
Separate units require coordinated feeder protection; integrated units include line-side vacuum switching as described in the selected configuration.
Technical Documents & Supply Scope
RVS Series Technical Documents
Original supplied product document, with ratings, configuration information and available drawings. The original source language and annotations are retained.
Inspection & Test Documentation
The supplied Raynen catalogue lists standards for semiconductor equipment, metal-enclosed equipment, enclosure protection and EMC. These references do not establish certification for the proposed supplied package.
Supply Scope To Confirm
Motor nameplate voltage and current; motor power; load torque and inertia; required acceleration time; permissible starting current; starts per hour; separate / integrated enclosure; upstream fault duty; bypass and protection; cable entry; controls and communications.
Maintenance Planning
Agree inspection of the SCR assemblies, cooling, fibre-optic links, contactors, protection and interlocks. Supplier documentation must cover the specific motor and starting duty.
6 kV Medium-Voltage Soft Starter FAQ
No. The supplied document describes a medium-voltage solid-state motor soft starter. Its primary purpose is controlled motor starting and stopping.
It is described as a soft starter with bypass operation after starting, not as a variable-frequency drive for continuous speed control.
The separate design needs a coordinated feeder cabinet. The integrated design combines line-side vacuum switching, soft-start control and bypass functions.
No. Select by motor rated current, load, starting time, duty cycle, ambient temperature and altitude. The catalogue selection tables contain inconsistent entries that need supplier confirmation.
The original integrated example in the supplied catalogue is labelled 10 kV. It is clearly marked as illustrative here and must be replaced by the approved 6 kV project schematic for engineering use.
Related Products
Explore related medium-voltage switchgear and motor starting equipment for power distribution and industrial applications.