SF6 Load Break Switches / 36 kV Indoor

Baocheng Electrical

36 kV Indoor SF6 Load Break Switch

A three-position indoor switching arrangement for ring main units, cable distribution cabinets and distribution switching stations. Specify the cabinet interface and required operating configuration for selection.

Indoor SF6 Load Break Switch

36 kV Indoor SF6 Load Break Switch

Closed / Open / Grounded

36 kV

Equipment rated voltage

Three Positions

Closed / Open / Grounded

630 / 800 A

Rated current options

50 / 60 Hz

Rated frequency options

Product Overview

The proposed indoor switch integrates closed, open and grounded contact positions in a gas-filled enclosure. Select the operating configuration and cabinet interface for the project. Switch-fuse combination duties require configuration-specific ratings and fuse coordination.

Technical Specifications

Confirm the selected current and frequency options, insulation requirements and switching duties with your quotation.

1
Rated equipment voltage
kV
36
2
Rated normal current
A
630 / 800
3
Rated frequency
Hz
50 / 60
4
Power-frequency withstand, phase-to-earth / open gap
kV
95 / 110
5
Lightning impulse withstand, phase-to-earth / open gap, peak
kV
185 / 215

Switch-Fuse Configuration

Provide the protected transformer rating and request the fuse selection and coordination data for the offered assembly.

Design and Operating Principle

Operating Mechanism

Operating and Interlocking

01 Grounding switch

The contact assembly provides a grounded position for the main circuit. Confirm the interlock arrangement for the selected cabinet.

02 Isolation Operation

The open position separates the main contacts. Confirm the isolation requirements against the approved assembly drawing.

03 Installation and Commissioning

Check cabinet clearances, operating access and mounting interfaces before installation.

Position Interlocking

The source describes interlocked closed, open and grounded positions.

36 kV Assembly Interfaces

Installation Information

Confirm the operating arrangement, cabinet interface and site conditions for the selected 36 kV assembly.

Confirm the operating arrangement, cabinet interface and site conditions for the selected 36 kV assembly.

36 kV Assembly Interfaces

Installation Information

Confirm the operating arrangement, cabinet interface and site conditions for the selected 36 kV assembly.

Applications & System Configurations

Suitable applications described in the source include ring main units, cable distribution cabinets and distribution switching stations.

Cabinet Integration

Specify the cabinet layout and operating requirements.

Cabinet Integration

Specify the cabinet layout and operating requirements.

Key Features & Procurement Guidelines

Coordinate the switch selection with the cabinet design and required switching duty.

Triple-Position Safety Interlock

Closed, open and grounded positions provide the operating states required for the cabinet arrangement.

Operating Duty

Specify the required operating cycle frequency and service duty for review.

Site Conditions

Provide ambient temperature, humidity and installation altitude for rating confirmation.

Procurement Guidelines

Include current, frequency, cabinet interfaces, mechanism, control supply and quantity in the enquiry.

Technical Documents and Supply Scope

Request the approved outline, terminal interfaces and operating instructions for the offered model.

Request test documentation identifying the actual model and tested configuration.

Confirm the mechanism, auxiliary contacts, control supply and any switch-fuse components.

36 kV Indoor SF6 Load Break Switch FAQ

The source describes closed, open and grounded positions.

Ring main units, cable distribution cabinets and distribution switching stations.

Request coordination information for the switch-fuse combination and the protected transformer.

Provide nominal system voltage and highest operating voltage for equipment selection.

Provide the cabinet layout, mechanism access and site conditions.

Include current, frequency, operating mechanism, control supply, quantity and the required switching duties.